Tripp Lite PDU 3-Phase Switched 208V 8.6kWA 21 C13 3 C19 0URM

Mfg # PDU3VSR10L2130 CDW # 2289446 | UNSPSC 39121017

Quick tech specs

  • 8.6kW 3-phase switched PDU 208V 0U vertical w/ 24 outlets and 10ft cord
  • Reports voltage frequency & load per-outlet or phase via Ethernet interface
  • Visual current meter and toolless button-mount installation
  • PDU / Power Distribution Unit / PDU Strip / Switched PDU / rack pdu / pdus / datacenter pdu / network pdu / Vertical PDU
  • 24 outlets (21 C13 / 3 C19); NEMA L21-30P 30A (3P+N+E) input 10ft cord
  • Temperature humidity and contact closure monitoring options
View All

Know your gear

PDU3VSR10L2130 Switched 3 phase 208V Zero U vertical rack PDU supports 8.6kW total output capacity. Includes 10 ft. / 3m input cord with NEMA L21-30P 30A (3P+N+E) 3 phase input plug and 24 208V individually controllable outlets arranged in 3 separately breakered single phase output load banks. Each single-phase output loading bank contains 8 outlets (7 C13, 1 C19). Visual meter with scroll button and PowerAlert remote monitoring interface enables real-time current monitoring for each output phase or individual receptacle. Supports 0U vertical rackmount installation with included mounting accessories. Toolless button-mount installation supported in compatible racks. Included cord retention brackets keep vital network equipment plugged in and continuously powered.




Tripp Lite 3 phase Switched PDU / Power Distribution Unit enables a variety of advanced network control and monitoring functions by giving IT managers the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or even per-receptacle. PowerAlert interface supports custom notification and control of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed per user-defined power-up and power-down sequences to ensure proper operation of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent powering of unauthorized hardware. PDU output current consumption in amps per-phase or per-receptacle can be displayed locally via visual meter and can be monitored via the web/network interface, with user-defined alarms to warn of potential overloads before critical IT mains or branch breakers trip. Supports in-rack environmental and security monitoring for advanced configurations with optional ENVIROSENSE temperature / humidity probe and rack access notification for up to 4 door sensors (SRSWITCH) or other user-supplied contact-closure sensors. Lighted display with scroll-button offers power consumption in amps for each phase or receptacle, IP-address self-identification and 180 degree display rotation for overhead or raised floor power feeds. Supports real-time monitoring of all reported functions with support for user-specified alarm and notification thresholds. Fully compatible with PowerAlert Network Management System / NMS Software, available via FREE download from www.tripplite.com