Tripp Lite Isolation Transformer 1800W Medical Surge 120V 6 Outlet TAA GSA

Mfg.Part: IS1800HG | CDW Part: 440041 | UNSPSC: 39121610
Availability: In Stock
Warranties
Was $1,068.00
Advertised Price
Lease Option
($20.40/month)
Product Details
  • 1 Listed Medical-Grade Isolation Transformers offer line isolation & continuous noise filtering
  • Hospital-grade plug & receptacles
  • Lowers cumulative leakage current of connected equipment to under 100 µA
  • Floating AC output prevents noise coupling
  • TAA Compliant
  • 6 Hospital-Grade Outlets/ NEMA 5-15R hospital-grade output receptacles/ Faraday shield/ medical isolation transformer/ hospital isolation transformer/ 10 ft power cord/ noise filtering
  • 2 Year Tripp Lite Warranty
View Full Product Details
Better Together
Tripp Lite Isolation Transformer 1800W Medical Surge 120V 6 Outlet TAA GSA
Quick View
Total Price:

Product Overview

Main Features
  • 1 Listed Medical-Grade Isolation Transformers offer line isolation & continuous noise filtering
  • Hospital-grade plug & receptacles
  • Lowers cumulative leakage current of connected equipment to under 100 µA
  • Floating AC output prevents noise coupling
  • TAA Compliant
  • 6 Hospital-Grade Outlets/ NEMA 5-15R hospital-grade output receptacles/ Faraday shield/ medical isolation transformer/ hospital isolation transformer/ 10 ft power cord/ noise filtering
  • 2 Year Tripp Lite Warranty
Tripp Lite Isolator series UL2601-1 listed Hospital Grade isolation transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. Internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas. Isolation transformer with Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps. Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients, and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes. Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat AandB ring wave and combination wave test surges to only 0.5V common mode. Model IS1800HG includes 6 widely spaced NEMA5-15R hospital grade output receptacles, a 6 ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch. Rugged all-metal unit housing ships ready for upright tower or wallmount placement in any industrial, medical, office or network environment.

Features:
Tripp Lite's IS1800HG Hospital Grade isolation transformer offers line isolation, continuous noise filtering and enhanced common mode surge suppression

Internal low-impedence isolation transformer with Faraday shield offers 100% isolation from the input AC line

Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas. -Reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps.

Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment

Serves as an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades

Removes EMI/RFI noise, utility switching transients, load generated harmonics and ground loops

Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes

Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels

Reduces 6000V IEEE587 Cat AandB ring wave and combination wave test surges to only 0.5V common mode

Includes 6 widely spaced NEMA5-20R hospital grade output receptacles, a 6 ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch

Ships with NEMA5-20P input plug installed, package includes NEMA5-15P user installable hospital grade replacement plug for compatiblity with common 15A wall receptacle

Rugged all-metal unit housing ships ready for upright tower or wallmount placement in any industrial, medical, office or network environment

2-year limited product warranty
Tripp Lite Isolation Transformer 1800W Medical Surge 120V 6 Outlet TAA GSA is rated5.00 out of5 by2.
Rated 5 out of 5 by from IS1800HG works very wellI purchase this in lieu of putting in a dedicated circuit for my home theater room. There was a lot of DC noise on the line and this device isolated it right away. Not sure if it is power of suggestion but the play back of music seems so much better and overall the quiet is very quiet. This thing seems to do what it claims. I am going to get another for my tv room. Oh, and there is a very slight hum from this device I was able to move it around enough that I don't hear it any longer.
Date published: 2015-02-12T00:00:00-05:00
Rated 5 out of 5 by from Great quality productI use the isolation xformer for my audio system and it works well the reduce noise and give blacker backgrounds.
Date published: 2019-12-16T00:00:00-05:00