Quick tech specs
- Single-Phase Metered Rackmount PDU w/ 18 Outlets and 12ft cord
- Single phase 7.4kW 32A 230V 2U horizontal rackmount PDU
- Attached IEC-309 32A (2P+E) input plug w/ 12ft cord; 18 total 230V outlets (2 C19 16 C13)
- PDU/ Power Distribution Unit/ Horizontal PDU/ PDU Strip/ rack pdu/ pdus/ metered pdu/ data center pdu/ network pdu
- Set of 2 current meters reports current in amps for each output load bank
- Mounting ears are reversible for front/rear facing rackmount installation
Know your gear
PDUMH32HV horizontal 2U metered rack PDU supports 32A maximum capacity at 230V. Includes 12 ft / 3.6m attached line cord with Blue IEC-309 32A input plug and 18 output receptacles (16 C13, 2 C19). Outlets are arranged in two separately breakered 9 outlet load banks. Set of two visual current meters tracks the output current of each load bank separately. Supports 2U rackmount installation in 19 inch racks. Included cord retention brackets keeps vital network equipment plugged in and continuously powered.
Tripp Lite Metered Power Distribution Units give IT Managers the ability to monitor network power consumption levels to prevent mains, generator, UPS or PDU overloads and to ensure proper load balance in complex redundant power applications. Built-in, easy to read, two-character LED display offers continuous PDU current monitoring data in one-amp increments. Switch-free unfiltered electrical pass-through reliably distributes UPS or generator power to multiple servers and vital networking equipment in rack enclosures, network closets and more. Included mounting brackets support horizontal installation in 19 inch racks or other surfaces, such as under-counter or wallmount configurations.
Key Features
•230V 32A metered Power Distribution Unit (PDU) in 2U horizontal rackmount form factor
•32A maximum capacity
•Attached Blue IEC-309 32A input plug with 12 ft. / 3.6m line cord
•18 total output receptacles (16 C13, 2 C19)
•Outlets are arranged in two separately breakered and metered 16A load banks (each with 8 C13 and 1 C19 outlet)
•Current meters offer the ability to visually monitor power consumption levels to prevent mains, generator, UPS or PDU overloads and to ensure proper load balance in complex redundant power applications
•Pair of easy to read, two-character LED displays offer continuous PDU current monitoring data in one-amp increments for each metered load bank
•Circuit breakers offer protection from overloads and short circuit fault conditions
•Switch-free unfiltered electrical pass-through reliably distributes UPS or generator power to critical networking equipment
•Cord retention brackets keep vital equipment plugs connected
Typical Applications
•Ideal for network configurations requiring a metered PDU
Package Includes
•2U metered PDU
•Mounting brackets
•Plug retention brackets
•User manual
Tripp Lite Metered Power Distribution Units give IT Managers the ability to monitor network power consumption levels to prevent mains, generator, UPS or PDU overloads and to ensure proper load balance in complex redundant power applications. Built-in, easy to read, two-character LED display offers continuous PDU current monitoring data in one-amp increments. Switch-free unfiltered electrical pass-through reliably distributes UPS or generator power to multiple servers and vital networking equipment in rack enclosures, network closets and more. Included mounting brackets support horizontal installation in 19 inch racks or other surfaces, such as under-counter or wallmount configurations.
Key Features
•230V 32A metered Power Distribution Unit (PDU) in 2U horizontal rackmount form factor
•32A maximum capacity
•Attached Blue IEC-309 32A input plug with 12 ft. / 3.6m line cord
•18 total output receptacles (16 C13, 2 C19)
•Outlets are arranged in two separately breakered and metered 16A load banks (each with 8 C13 and 1 C19 outlet)
•Current meters offer the ability to visually monitor power consumption levels to prevent mains, generator, UPS or PDU overloads and to ensure proper load balance in complex redundant power applications
•Pair of easy to read, two-character LED displays offer continuous PDU current monitoring data in one-amp increments for each metered load bank
•Circuit breakers offer protection from overloads and short circuit fault conditions
•Switch-free unfiltered electrical pass-through reliably distributes UPS or generator power to critical networking equipment
•Cord retention brackets keep vital equipment plugs connected
Typical Applications
•Ideal for network configurations requiring a metered PDU
Package Includes
•2U metered PDU
•Mounting brackets
•Plug retention brackets
•User manual