Powerware 9170+ 12-slot cabinet

Mfg.Part: PW12S12K | CDW Part: 321936 | UNSPSC: 43201601
  • Power array cabinet
  • Rack-mountable
  • 12000 VA power capacity
  • 12000 VA power capacity
  • 8 min battery run time (up to)
  • 12000 VA power provided
  • AC 120/208/240 V
View Full

This item was discontinued on May 02, 2018

Contact Sales Assistance
(800) 800-4239, Monday-Friday 7am-7:30pm CT

Email our Sales Assistance Team , Response within 24 Hours

Better Together
Quick View
Total Price:

Product Overview

Main Features
  • Power array cabinet
  • Rack-mountable
  • 12000 VA power capacity
  • 12000 VA power capacity
  • 8 min battery run time (up to)
  • 12000 VA power provided
  • AC 120/208/240 V
  • 2 years warranty
  • 2 years warranty
Reliable on-line, high frequency double conversion power protection that's scalable for midrange IT applications

With a scaleable, modular and redundant design, the Powerware 9170+ Rackmount UPS provides advanced backup power and power quality management and offers the highest level of power protection and power quality of any Rackmount UPS power supply in the 3-18 KVA range.

The Powerware 9170+ Rackmount UPS delivers ideal power management for server farms, networks, telecommunications, Internet service providers and other mission-critical applications for the best UPS power protection against all nine common power quality problems.

Powerware 9170+ 12-slot cabinet is rated 5.0 out of 5 by 3.
Rated 5 out of 5 by from Keeps the juice flowing day and night. Monitoring and shut down. Had one in our datacenter for 10 years and just keeps chugging along.
Date published: 2015-08-07
Rated 5 out of 5 by from The 9170 has brought much needed stability to our power infrastructure. We have ours currently configured at 12Kw. I recommend that if you are implementing any enterprise UPS, be thoughtful about how you configure the device with regards to power hook ups. We purchased a configuration which had NEMA 20's already hardwired into the back of the power distribution panel. It took minutes to hook up and operationalize, however we learned that we could not have a "by-pass switch" wired into the UPS. Therefore any maintenance which needs to be performed on the unit must be done while the unit is not under load. If we purchased the separate power distribution panel and hardwired the device into it, we could have added a bypass switch which would have allowed the UPS to be bypassed during maintenance. Also be mindful of the power balance. There is an A circuit and a B circuit. Make sure you have an even load across both to avoid issues. Our vendor recommended no more than a 15% variance between the two.
Date published: 2012-07-17
Rated 5 out of 5 by from Installed this unit in January. So far so good. The only downside for me is that Spiceworks thinks the UPS is old and needs to be replaced. For some reason it thinks it is a failing device. Other than that the utilities are good and we should get some good power out of it. I like the power manager software as well.
Date published: 2012-05-14